STANDARD OPERATING PROCEDURE SANITIZATION OF MANUFACTURING AND PACKING AREAS& EQUIPMENT (ALL AREAS EXCEPT LIQUID LINE-1)
STANDARD
OPERATING PROCEDURE
SUBJECT:
SANITIZATION OF
MANUFACTURING AND PACKING AREAS& EQUIPMENT
(ALL AREAS EXCEPT LIQUID
LINE-1)
|
DEPARTMENT : QA
SOP
NO. :
Page
No :
Effective
Date :
Next
Review :
SOP
REVISION :
|
1.0 OBJECTIVE:
To provide guidelines for Sanitization of
Manufacturing areas equipment.
2.0 POLICY:
To
ensure establish a procedure for sanitization of manufacturing and Packing areas and equipment.
3.0 PROCEDURE:
3.1
Samples are to be drawn only after
the Sanitization.
3.2 The
position for the swab contact includes top of the lid ends of the tank, inside
of the lids and the inner surface of the tank, shaft of the agitator, pump
housing and inside of the discharge
points.
3.3
Rub the moistened pre-sterilized
swab approximately three times.
3.4 Aseptically
break swab off into 5ml phosphate buffer, put the tube on the Cyclo mixer for
10 min.
3.5 Withdraw
1 ml from buffer from (step 3.4) & pour in two Petri dishes having plate
count agar (Himedia M0910). Transfer the left over buffer into 10ml of modified
lecithin broth (Hi media M 976).
3.6
Incubate the plates at 32-37 deg. C
for 48 hrs.
3.7
Count the number of colonies. It
should not exceed 100 cfu
4.0 FREQUENCY: Limits & frequency to be specified by Parent
Company.
5.0 RESPONSIBILITY: Executive QA / Executive Production.
6.0 REVIEW
GUIDE: Equipment Sanitization
log.
6.0 ANNEXURE: --------
7.0 SOPs DISTRIBUTION:
This
SOP shall be distributed to following Departments:
Name of the Department
|
Master Copy
|
Circulatory Copy
|
QA/QC
|
√
|
√
|
Production
|
x
|
x
|
Warehouse
|
x
|
x
|
General
|
x
|
x
|
Maintenance
|
x
|
x
|
Comments